For many projects, this “simple” A‑to‑B connection is where time, cost and risk creep in. Multiple components to coordinate, on-site insulation work, extra joints and wider trenches than expected, all adding up to longer installation times and more disruption.
Flexalen® 600 Heat Pump Connection Set: A Simpler Way to Connect Heat Pumps
As Europe accelerates its shift toward heat pumps driven by the EU Green Deal, REPowerEU and national regulations such as Germany's GEG, one very practical question keeps coming back from installers and engineers: how do you connect the outdoor unit to the building quickly, neatly and reliably?
The hidden costs of heat pump connections
What is the Flexalen® 600 Heat Pump Connection Set?
The Flexalen® 600 Heat Pump Connection Set (Short Length Package) is a compact, ready-to-install pre-insulated pipe set specifically for heat pump connections. It combines the performance of Flexalen® 600 HP with everything needed for a typical A‑to‑B connection in one box:
- Flexible PB‑1 service pipes with oxygen barrier
- Integrated conduit pipes for power and control cables
- High-performance closed-cell polyolefin foam insulation
- Corrugated PE outer casing for mechanical protection
- Compression fittings, end caps and warning tape included
Your most-asked questions, answered
How can I minimise excavation and disruption?
Flexible pre-insulated pipe requires a narrower trench than rigid systems, follows ground contours without extra fittings, and has a bending radius of just 0.5 to 0.6 m. In the Assentoft project (Denmark), the homeowner dug the trench by hand — excavation and laying took about 7.5 hours for an 18.5 m connection.
What insulation is required for outdoor heat pump pipes?
Exterior and underground pipework needs closed-cell, moisture-resistant insulation with a protective outer layer. Standard foam or rubber insulation is not suitable for permanent outdoor use. Pre-insulated piping integrates insulation and a sealed PE casing at the factory, ensuring consistent quality regardless of installer experience.
Does poor insulation really affect heat pump performance?
Yes. Inadequate pipe insulation can reduce a heat pump’s COP from over 4 to around 3, a 25% efficiency loss that translates directly into higher electricity bills and potential callbacks.
Proven in a real residential project
In Assentoft, Denmark, a family converted from gas to a 12 kW air-to-water heat pump. The Flexalen connection set enabled an 18.5 m underground pipe run installed by hand in less than a day, achieving a SCOP of 5.21 and AAA+ energy labelling.
Need more information?
Why work with us
Thermaflex combines decades of expertise with a commitment to sustainable innovation. As your trusted partner, we deliver more than products, we provide comprehensive technical support, proven solutions, and collaborative partnerships that help you achieve project success, regulatory compliance, and long-term operational efficiency across various markets and applications worldwide.
- Expert support
- Global experience
- Reliable delivery
- Flexible solutions
- Innovative approach
- Sustainable practices
- Technical guidance
- Long-term partnerships
- Proven quality
- Customer-focused